Browse all practice questions for the Embraer Regional Jet (ERJ) Systems Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Embraer Regional Jet (ERJ) Systems Practice Exam – Prep & Study Guide course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Which flap setting is designated for takeoff purposes?
  • What is the primary purpose of standard operating procedures (SOPs) for the flight crew?
  • What must the TO DATASET MENU be set to when the OAT is from 5 to 10C?
  • Describe the emergency oxygen system in the ERJ-145.
  • What components are included in the DC HOT BATT BUS 1/2?
  • What is the AC power priority sequence in aviation systems?
  • Which flaps are used for a go-around?
  • What is the recommended practice for engine shutdown after landing?
  • What purpose does the Indication, Crew Alerting, and Logging System (ICALS) serve?
  • When can RTO be disarmed?
  • What is the function of ACMP 3A after a dual engine failure?
  • How can the crew respond to an engine failure during flight?
  • Which message indicates that the RAT did not deploy during an electrical emergency?
  • Which system is typically checked remotely via the MCDU?
  • How can the H-PBIT be initiated?
  • What is the pressure configuration of the fuel system in the ERJ-145?
  • Which AC buses become energized after the RAT deploys?
  • How does high altitude flight generally impact engine performance?
  • What does the E-PBIT automatically detect?
  • How does the ERJ-145 handle ice accumulation on the wings?
  • How does the ERJ-145 achieve effective fuel management during flight?
  • How is primary control of the flight control surfaces accomplished?
  • What is the function of DC fuel pumps in aircraft systems?
  • When will the APU automatically shut down in the air?
  • What happens to the Green Dot during flap retraction when the F-bug disappears?
  • What triggers the automatic deployment of the RAT?
  • Under which circumstance would you have to notify maintenance after a slide deployment?
  • What is the maximum crew oxygen supply time at 100% concentration?
  • Identify the components involved in the ERJ's fire protection system.
  • How is windshear guidance manually activated?
  • What happens when smoke is detected in the FWD cargo?
  • When will ACMP 1 activate automatically on the ground?
  • What is the fail-safe state for the Engine A/I system?
  • Describe the emergency exit configuration in the ERJ-145.
  • When might packs and recirc fans turn off?
  • What is required for the ADS Probe heat in relation to engine operation?
  • Under what condition will GA thrust be automatically set on the EICAS?
  • What occurs to the FCM in direct mode?
  • What is the main function of the RAT in the Embraer Regional Jet?
  • What component is vital for the maintenance of cabin temperature in the ERJ-145?
  • Which instruments provide information for flight attitude in the ERJ-145?
  • Which hydraulic pumps remain operational after a dual IDG failure?
  • What conditions require setting the TO DATASET MENU to ALL when OAT is less than 5C?
  • What is the primary role of the thrust reversers in the ERJ-145?
  • What type of cockpit displays are utilized in the ERJ-145?
  • In what conditions would the flight crew use the Aircraft Communications Addressing and Reporting System (ACARS)?
  • Which ADS system would primarily utilize TAT 1 and ADSP 1/2?
  • What is the role of the pressure relief valves?
  • What light system indicates the landing gear status in the ERJ-145?
  • When a fire handle is pulled, which system is NOT closed?
  • Under what condition is the antiskid protection deactivated?
  • What is the main function of the ADS systems in the aircraft?
  • What type of communication systems are installed in the ERJ-145?
  • At what wheel speed is locked wheel protection active on the ground?
  • During a go-around procedure, what is the first action the crew should take?
  • Under what condition will ACMP 3B turn on automatically in the air?
  • What condition activates TAT heaters?
  • How does the ERJ-145's weather radar system function?
  • What is the distinction between the OFF and DISC settings on the IDG knob?
  • In what situation does ACMP 1/2 turn on automatically in flight?
  • In MAN mode, what happens when the DUMP button is pressed?
  • What is the function of the TRUs and inverter in the ERJ systems?
  • Which system is utilized to extend the gear in an Embraer Regional Jet?
  • Which component is responsible for converting AC to DC power?
  • What must happen for the water dump light to turn off?
  • What is the first condition needed for TATs to be heated?
  • When will the DC fuel pump automatically engage if there is no AC power?
  • What type of data does the Central Maintenance Computer (CMC) collect?
  • What is the importance of maintaining cabin pressure during climbs and descents?
  • What helps maintain the hydraulic pressure in the ERJ hydraulic system?
  • How is cabin pressurization controlled in the ERJ series?
  • Which AC buses are energized during an electrical emergency before the RAT deploys?
  • What operates the cabin door of the ERJ-145?
  • What flap setting is utilized exclusively for landing?
  • During an electrical emergency, what is the first step taken to respond?
  • What indicates that the ERJ-145 cabin door is locked?
  • What is the appropriate action when the APU is in operation and the AC pump is unavailable?
  • When is the Green Dot utilized for emergency approaches?
  • When is CLB thrust automatically set on the EICAS?
  • Which navigation aids does the ERJ-145 primarily use?
  • Which of the following maintenance checks is NOT a regular requirement for the ERJ aircraft?
  • What is the primary function of the cabin pressure control system in an aircraft?
  • What is the purpose of the ERJ's auto-throttle system?
  • What interrupts the H-PBIT?
  • What automatically sets CRZ thrust on the EICAS?
  • What is the cruising speed of the ERJ-145?
  • Under which conditions will the APU automatically shut down on the ground?
  • What action should be taken regarding landing gear during a successful go-around?
  • Which situation interrupts the E-PBIT?
  • What is the primary function of the outflow valve?
  • How many AC power sources are required for the windshield heat to function normally?
  • What duration of crew oxygen is available in NORM mode?
  • What indicates a problem if FADEC aborts the start of an engine?
  • What is the primary function of the aircraft's autopilot system in the ERJ-145?
  • What indicates a high-rate extinguishing action in the cargo area?
  • What happens to the AC STBY BUS after the RAT deploys?
  • What types of circuit breakers (CBs) are used in the Embraer Regional Jet systems?
  • What is the primary purpose of the auxiliary power unit (APU) in the ERJ?
  • What occurs when the DUMP button is pressed in AUTO or LFE mode?
  • Which component is crucial for monitoring cabin pressure in an aircraft?
  • Which navigation equipment remains available during an electrical emergency?
  • Which type of check is the most comprehensive and includes major repairs for the ERJ aircraft?
  • Why do memory items need to be performed when FADEC aborts a start?
  • Under which condition will the ATTCS engage?
  • Which system manages the fuel flow in the ERJ-145?
  • Which of the following conditions must be met for RTO (Rejected Takeoff) to be armed?
  • What must be true for RTO to be selected?
  • Which of the following does NOT indicate a cargo fire condition?
  • What causes the yellow IDG light to illuminate?
  • Why is it important to maintain a gradual transition of cabin pressure?
  • What condition allows for the activation of the automatic wheel braking system?
  • What action should be taken after an inadvertent slide deployment?
  • What are the primary visual instruments in the ERJ-145 cockpit?
  • What role does the trim wheel play in aircraft operations?
  • How do flaps 4 and 5 differ in purpose?
  • What is primarily needed for the APU fuel pump to operate when engines are off?
  • What indicates that APU is running properly?
  • What materials are primarily used in the ERJ-145's airframe construction?
  • What triggers a FADEC to abort an engine start?
  • What is the airspeed threshold for speed brakes to automatically retract during flight?
  • What is the primary material used in the construction of the ERJ-145's fuselage?
  • How long does it take for a Traffic Advisory (TA) and Resolution Advisory (RA) to populate before a potential collision?
  • When implementing the Cargo Fire Suppression Rule of 3, what is required for a non-annunciated fire?
  • What position does the throttle control lever have during takeoff?
  • What should the settings be when operating on surfaces like snow or ice?
  • Which phase of flight requires the most active management of cabin pressure?
  • When will the PTU activate automatically?
  • Which sensors contribute to the aircraft's air data system?
  • What type of inspections are required for the ERJ's landing gear?
  • What triggers the automatic engagement of the AC fuel pump 1 or 2?
  • Which system is used to control the ERJ-145's hydraulic functions?
  • What is the startup sequence for the engines in the ERJ-145?
  • Which situation indicates that ADSPs are working as intended?
  • Why are weight and balance calculations important before flight?
  • How does the cabin pressure control system affect the passenger experience during altitude changes?
  • What is one of the main functions of the Traffic Collision Avoidance System (TCAS)?
  • What happens to cabin pressure as an aircraft climbs?
  • Which of the following flight controls utilizes the hydraulic system?
  • What is a common feature of advanced cabin pressure control systems?
  • Which hydraulic pump is activated during an EDP 1 failure?
  • What systems are monitored by the ERJ-145's Electronic Centralized Aircraft Monitor (ECAM)?
  • How does the stall warning system operate in the ERJ-145?
  • At what altitude and time does CRZ thrust engage automatically?
  • Under what conditions will the H-PBIT start automatically?
  • What is the duration of the E-PBIT?
  • When must the A/I system be selected ON while taxiing?
  • Explain the significance of the ERJ's yaw damper system.
  • What is the operational duration of the H-PBIT?
  • Which of the following is a consequence of improper cabin pressure management?
  • During a fire test, how many overhead lights are activated?
  • What is the primary purpose of the engine fire extinguishing system?
  • In case of a cabin pressure failure, what immediate action should be taken?
  • What is the function of the pitch trim system in the ERJ?
  • What is required to reset a fire handle once it has been pulled?
  • During a fire, how many master warning lights are activated?
  • When manually starting H-PBIT, how should the hydraulic pumps be turned on?
  • What is the role of fluid reservoirs in the ERJ hydraulic system?
  • What measures are taken to ensure cabin safety during turbulence?
  • How many ice detectors must be operational for the A/I system to work in auto mode?
  • Which flap setting corresponds to Flaps 5 during landing?
  • When is ADS Probe heat required on the ground?
  • What are the main components of the ERJ-145's electrical system?
  • Which of the following is a safeguard for the ERJ's electrical system?
  • What parameter must be checked for an OK takeoff according to the criteria?
  • What does a sudden change in cabin pressure signal about the system?
  • Under which condition does ACMP 2 turn on automatically on the ground?
  • Which component is included in the fire test list?
  • What condition deactivates touchdown protection?
  • Which of the following speed definitions applies to the Green Dot on the Embraer Regional Jet?
  • What must occur for thrust settings to switch to CLB phase during a climb?
  • Which of the following is NOT one of the EICAS messages during a fire event?
  • What indicates a properly functioning cabin pressure control system in an ERJ?
  • Explain the role of the fasten seatbelt signs during flight operations.
  • How is the landing gear retracted in the ERJ-145?
  • When will RSV thrust automatically be set on EICAS?
  • What is required to start the APU on DC power?
  • Which system or mechanism is responsible for ADS reversion in the Embraer Regional Jet?
  • Under which condition are ADSPs heated?
  • What happens to ACMP after the parking brake is engaged for 6 minutes?
  • What usually triggers the cabin pressure control system to make adjustments during flight?
  • What defines when GA thrust is set automatically on EICAS?
  • What type of control does the cabin pressure control system use to maintain pressure gradients?
  • Which system is included in the ERJ-145’s collision avoidance technology?
  • How does the ERJ-145 ensure efficient airflow in its engines?
  • When is windshear guidance automatically activated?
  • What is a critical condition for APU shutdown in flight?
  • What backup system is available for the ERJ's flight controls?
  • Which components are found on the AC ESS BUS?
  • How are cabin lights controlled in the ERJ-145?
  • What type of de-icing system is present in the ERJ-145?
  • In what circumstances is the ram air turbine (RAT) deployed?
  • What is the ultimate goal of cabin pressure control systems in ERJs?
  • What is a critical consideration during the preflight inspection of the ERJ?
  • What happens to TAT heaters when the airspeed drops below 45 knots while landing?
  • Which feature enhances the safety of the ERJ-145 during unfavorable weather conditions?
  • What condition is necessary for RTO to be applied?
  • How many ITT fire indications are there when a fire is detected?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy